Application
Instructions
DESCRIPTION OF PRODUCT: A full padded hand mitt with finger separators.
Rx ONLY
Finger Control Mitts
© 2012 Posey Company. All rights reserved.
I9292 REV C 030612
ADDITIONAL SAFETY AND LAUNDERING
INSTRUCTIONS ON OTHER SIDE
2815
2816
Application Instructions
(Repeat steps 1-3 for each mitt):
1. Insert the patient’s hand into the mitt, palm down. Separate
the fingers so each finger fits into its own slot.
2. Wrap the wrist strap around the smallest part of the patient’s
wrist, through the plastic ring, and secure with the hook and
loop fastener.
3. Slide ONE finger (flat) between the device and the inside of
the patient’s wrist to ensure proper fit. The strap must be
snug, but not compromise circulation.
Posey Finger Control Mitts
REF
2815 Finger Control Mitts, Open End
REF
2816 Finger Control Mitts, Closed End
Indications For Use:
• Patientsassessedtobeatriskofdisruptinglife-savingtreatments(e.g.,chronictube
pulling).
• Patientsassessedtobeatriskoflinepulling,whichmaypreventmonitoringofvital
signs.
• Patientswhosepicking,pulling,scratching,orpeelingexacerbatesaskincondition,
causes self-injury, or compromises wound site integrity.
Contraindications:
• DO NOT use on a patient who is or becomes highly aggressive, combative, agitated, or
suicidal.
Adverse Reactions:
• Severeemotional,psychological,orphysicalproblemsmayoccur:iftheapplieddevice
is uncomfortable; or if it severely limits movement. If symptoms of these problems
ever appear for any reason, get help from a qualified medical authority and find a less
restrictive, product or intervention.
BED SAFETY
• ALWAYSuseHospitalBedSafety
Workgroup(HBSW)(http://www.fda.gov
searchkeyword“HBSW”)compliantside
railsintheUPpositionandllALLgapsto
reducetheriskofentrapment.
• Usesiderailcoversandgapprotectorstohelppreventthe
patient’sbodyfromgoingunder,around,throughor
betweenthesiderails.Afailuretodosomayresultin
seriousinjuryordeathifapatientbecomessuspendedor
entrapped.Poseyoffersafullrangeofsiderailpadsand/
orgapprotectorstocovergaps.
MONITORPERFACILITYPOLICY.
Checktoensurethat:
• Mittsareproperlysecured.Ifappliedtootightly,
circulationwillberestricted;ifappliedtooloosely,the
patientmaybeabletosliphisorherlimbfromthedevice;
• Mittsareintact,nottornordamaged,andhookandloop
closessecurely.DONOTallowpatientstoingestmitt
material;
• Thepatientcannotusehisorherteethorotherwise
removethedeviceandinictself-injury;
• Monitorcloselywhenthepatientisoutofbed.Patients
whoambulatewhilewearingthisdevicemaybeatriskof
injuryfromafall.
• NEVER use mitts on a patient:
• If an IV or wound site could be compromised by the device; or
• With a dislocation or fracture on the affected limb.
See the Posey Catalog for other options for such a patient.
ADDITIONALORDIFFERENTBODYORLIMBRESTRAINTS
MAYBENEEDED(SeePoseyCatalog):
• Toreducetheriskofthepatientgettingaccesstotheline/
wound/tubesite;
• Topreventthepatientfromailingorbuckingupand
downandcausingself-injury.
PoseyCompany•5635PeckRoad,Arcadia,CA91006-0020USA•www.posey.com
Phone:1.800.447.6739or1.626.443.3143•Fax:1.800.767.3933or1.626.443.5014
MDSS GmbH
Schiffgraben 41
D-30175 Hannover, Germany
EC REP